FSI Contractorship Application
Classes of Fire Service Installation Contractors
| Class
1 |
Registered contractors who are fit to install, maintain, repair
and inspect any fire service installation or equipment (other
than portable equipment) which contains an electrical circuit
or other apparatus for the detection and warning, by alarm
or otherwise, or smoke or fire.
Such
fire service installation or equipment includes drencher system,
dust detection system, dynamic smoke extraction system, fire
detection system, gas detection system, gas extraction system,
pressurization of staircase, static smoke extraction system
and ventilation/air conditioning control system.
|
| Class
2 |
Registered contractors who are fit to install, maintain, repair
and inspect any fire service installation or equipment (other
than portable equipment) which contains :- |
| |
a) |
pipes
and fittings designed or adapted to carry water or some other
fire extinguishing medium; or |
| |
b)
|
any
type of electrical apparatus other than those specified in class
1. |
| |
Such
fire service installation or equipment includes audio/visual
advisory system, automatic actuating devices, automatic fixed
installations other than water, automatic fixed installation
using water, deluge system, drencher system, dynamic smoke
extraction system, emergency generator, emergency lighting,
exit sign, fire alarm system, fire hydrant/hose reel system,
fixed automatically operated approved appliance, fixed foam
system, gas extraction system, pressurization of staircase,
ring main system with fixed pump(s), sprinkler system, static
smoke extraction system, street fire hydrant system, ventilation/air
conditioning control system, water mist system, water spray
system and water supply.
|
| Class
3 |
Registered
contractors who are fit to maintain, repair and inspect portable
equipment.
Such
fire service installation or equipment includes fixed automatically
operated approved appliance and portable hand-operated approved
appliance.
|
Table showing the systems/installations/equipment
may be required to be installed in various premises under
the “Code of Practice for Minimum Fire Service Installations
and Equipment” and the appropriate classes of registered contractors
for such works.
| Fire
service systems/ installations/ equipment |
Class
1
|
Class
1 +
Class 2
|
Class
2 |
Class
3
|
| Audio/visual
advisory system
|
-
|
 *
|
|
-
|
| Automatic
actuating devices
|
-
|
 *
|
|
-
|
| Automatic
fixed installations other than water
|
-
|
 *
|
|
-
|
|
Automatic fixed installation using water |
-
|
 *
|
|
-
|
|
|
-
|
 *
|
|
-
|
| Drencher
system |
- |
|
- |
- |
| Dust
detection system |
|
- |
- |
- |
| Dynamic
smoke extraction system |
- |
|
- |
- |
| Emergency
generator |
- |
- |
|
- |
| Emergency
lighting |
- |
- |
|
- |
| Exit
sign |
- |
- |
|
- |
| Fire
alarm system |
- |
- |
|
- |
| Fire
control centre |
- |
- |
- |
- |
| Fire
detection system |
|
- |
- |
- |
| Fire
hydrant/hose reel system |
- |
- |
|
- |
| Fireman’s
lift |
- |
- |
- |
- |
| Firefighting
and rescue stairway |
- |
- |
- |
- |
| Fixed
automatically operated approved appliance |
- |
- |
|
|
| Fixed
foam system |
- |
- |
|
- |
| Gas
detection system |
|
- |
- |
- |
| Gas
extraction system |
- |
|
- |
- |
| Portable
hand-operated approved appliance # |
- |
- |
- |
|
| Pressurization
of staircase |
- |
|
- |
- |
| Ring
main system with fixed pump(s) |
- |
- |
|
- |
| Sprinkler
system |
- |
- |
|
- |
| Static
smoke extraction system |
- |
|
- |
- |
| Street
fire hydrant system |
- |
- |
|
- |
| Supply
tank |
- |
- |
- |
- |
| Ventilation/air
conditioning control system |
- |
|
- |
- |
| Water
mist system |
- |
- |
|
- |
| Water
spray system |
- |
- |
|
- |
| Water
supply |
- |
- |
|
- |
| Legend
: |
*
= for system with fire detection system |
| |
#=
refers to fire extinguishers, fire blankets and sand buckets
etc. |
Registration
Procedures
| Information
to Applicants |
Class 1
|
Class 2
|
Class 3
|
| Application
forms
|
|
|
| Document
checklist
|
|
|
| Notes
to Applicants
|
|
|
| Written
Exam Syllabus
|
-
|
|
| Syllabus for Practical Test
|
-
|
|
| Points to Note for Candidates of Practical Test |
- |
|
| Exam
Sampler
|
-
|
|
| Exam
Instructions
|
-
|
|
| Performance
Pledge
|
|
|
|
Workshop Facilities |
|
|
|
|
|
|
| Workshop
Equipment Ownership Undertaking Form |
|
* The Class 3 written
exam will be changed to a computerised exam (multiple-choice questions)
w.e.f. July 2008
Notes
to Applicants for Registration as
Fire Service Installation (FSI) Contractors in Classes 1 and/or
2
A. Application
Procedures
-
Application
should be made by filling in Form 1 [FS
250A (English) or FS250C
(Chinese)]. Completed application forms, the document
checklist, together with all documents specified in Section
B below may be sent by post or delivered to the following
address:-
Fire
Service Installation Contractors' Registration Registry
Licensing and Certification Command Headquarters
Fire Services Department
5/F, South Wing,
Fire Services Headquarters Building,
1 Hong Chong Road,
Tsim Sha Tsui East,
Kowloon.
-
After
all required documents submitted by the applicant have been
found satisfactory, the applicant together with his proposed
qualified person(s) may be required to produce original copies
of supporting documents for verification and to clarify information
relating to the application in person.
-
If the
proposed qualified person(s) is/are accepted by the Fire Services
Department, a payment notice will be mailed to the applicant
for payment of registration fee. Applicant should settle the
registration fee by following the instructions stated in the
payment notice.
-
Workshop
inspection will be arranged by the Fire Services Department
when all the required formalities have been completed. During
the inspection, all basic equipment required for an FSI Contractor
in Classes 1 and/or 2 should be made available for inspection.
The applicant and all qualified person(s) should be present
to demonstrate the use of the required equipment and answer
questions relating to the application during the workshop
inspection.
-
If more
than one workshop is proposed for registration, the application
will only be approved after all proposed workshops have been
inspected and found to be satisfactory by the Fire Services
Department.
- Civil servant / ex-civil
servant should comply with all the government rules and regulations
on outside work / outside employment during the pre-retirement
leave and post-retirement period before submitting the application.
B.
Supporting documents required
| 1. |
Proof of
company registration, including: |
| |
|
| |
(i) |
Officially
certified true copy of the company's current Business Registration
Certificate, obtainable from the Business Registration Office
of Inland Revenue Department; |
| |
|
|
| |
(ii) |
Officially certified true copy of the company's application
form for registration under the Business Registration Regulations,
obtainable from the Business Registration Office of Inland
Revenue Department; and
|
| |
|
|
| |
(iii) |
In
case of a limited liability company, a printed copy of the
Memorandum and Articles of Association together with an
officially certified true copy of the Certificate of Incorporation
of this limited liability company, obtainable from the Companies
Registry. |
| |
|
|
| 2. |
Proof of
the employment status and academic/professional qualifications
of the proposed Qualified Persons including: |
| |
|
| |
(i) |
Employment Status |
| |
|
|
| |
|
-
Copy
of employer's Mandatory Provident Fund contribution
record or tax return on staff remuneration
-
Written confirmation of the date of employment
-
Written
confirmation of the proposed Qualified Persons' being
full-time employees and that they are not at the same
time being employed by another registered Fire Service
Installation Contractor
|
| |
(ii) |
Academic/professional
qualifications |
| |
|
|
| |
|
-
Class
1: Copy of graduation certificate of requisite* degree
programme in electrical engineering. The degree holder's
name, degree awarded and the period of study should
be shown on the certificate.
-
Class
2: Copy of graduation certificate of requisite* diploma
or higher certificate course in electrical engineering
and Copy of Grade I plumber's licence issued under the
Waterworks Ordinance (Cap.102).
|
| |
|
* Requisite qualifications
of proposed Qualified Persons are: |
| |
|
|
| |
|
Class
1: The applicant or one of the applicant's directors, employees
or partners holding a degree in electrical engineering satisfying
the examination requirements (Parts I and II) of the Council
of Engineering Institutions for corporate membership of
the Institution of Electrical Engineers.
Class
2: The applicant or one of the applicant's directors, employees
or partners holding a Grade I plumbers licence issued under
the Waterworks Ordinance (Cap. 102); the applicant or one
of the applicant's directors, employees or partners holding
a diploma from the Hong Kong Polytechnic University (former
Hong Kong Polytechnic) or a Technical Institute or a higher
certificate in Electrical Engineering.
|
| |
|
|
| 3. |
Particulars
of all persons authorized to sign a certificate in accordance
with Regulation 3A of the Fire Service (Installation Contractors)
Regulations, including their names, employment status (e.g.
director, partner or employee) with documentary proof, HKID
numbers, copies of HKID and specimen signatures. Unless
issued by other representatives appointed by the applicant,
only correspondences signed by the above persons in relation
to the registration will be recognized and processed by
this Department. |
| |
|
|
| 4. |
In
case of Class 1, proof showing that the applicant or at
least one of the applicant's directors, employees or partners
is a manufacturer, designer or an authorized agent of an
electrical circuit or other apparatus recognized by the
Director of Fire Services, for the detection by alarm or
otherwise of smoke or fire, including:
|
| |
|
|
| |
(i) |
Manufacturer / designer |
| |
|
|
| |
|
Copy of product acceptance
letter of a product manufactured by his company issued by
the Director of Fire Services. |
| |
|
|
| |
(ii) |
Authorized agent |
| |
|
|
| |
|
-
Original
copy of appointment letter issued by a manufacturer.
Name of the authorized agent, the appointment period
and the model and type of products accepted by the Director
of Fire Services which are covered by the appointment,
should be specified on the letter.
-
Copy
of product acceptance letter of the specified model
and type of products issued by the Director of Fire
Services
|
| 5. |
Particulars
of the proposed workshop (should be an independent area of
not less than 10m2), including: |
| |
|
|
| |
(i) |
|
| |
|
|
| |
(ii) |
Chinese
and English addresses of the premises where the workshop
will locate |
| |
|
|
| |
(iii) |
Copy
of the purchase / lease agreement of the premises
|
| |
|
|
| |
(iv) |
Authorization
letter issued by the owner / tenant of the premises and
written explanation on the relationship between the owner
/ tenant and the applicant, if the premises is not purchased
/ leased by the applicant. |
| |
|
|
| |
(v) |
Copy
of receipts for payment of Government rates or utility charges
if the lease agreement has not been stamped |
| |
|
|
| |
(vi) |
Layout
plan |
( Rev .
4/2005)
Top
Equipment List
Basic
requirements of equipment for Classes 1, 2 and 3 registered FSI
contractors
Class
1
- Threading
Tools (for conduit)
- Bending
Machine (for conduit)
- Electric
Drill
- Multi-tester
(AVO)
- Detector
Tester (Measuring of Detector Sensitivity)
- Automatic
Detector Tester
- For MICC Cable:
(a) Rotary Stripper or Fork-ended Stripper together with Ringing Tool
(b) Plate Crimper
(c) Pot Wrench
(d) Bending Lever
(e) Cable Gauge
- General
Tools (Screwdriver, Pliers, Spanner etc.)
-
Insulation
Tester
*
The equipment must be owned by the applicant. The workshop
equipment ownership undertaking form must be completed
before workshop inspection.
Class
2
- Threading
Tools (for conduit)
-
Threading Machine (for water pipe)
- Bending
Machine (for conduit)
- Electric
Drill
- Multi-tester
(AVO)
- For MICC Cable:
(a) Rotary Stripper or Fork-ended Stripper together with Ringing Tool
(b) Plate Crimper
(c) Pot Wrench
(d) Bending Lever
(e) Cable Gauge
- General
Tools (Screwdriver, Pliers, Spanner etc.)
- Welding
Machine
- Manual
/ Electric Hydraulic Pump with Pressure Gauge
- Flow
Meter and Pressure Gauge (for proving test)
- Level
Measuring Meter (for gas system)
- Scale
(up to 200 kg)
- Insulation
Tester
- Earth
Resistance Tester
* The equipment must be owned by the applicant. The workshop
equipment ownership undertaking form must be completed
before workshop inspection.
Class
3
-
General Tools (Screwdriver, Pliers, Spanner etc.)
-
Manual / Electric Hydraulic Pump with Pressure Gauge
-
Scales
-
Adaptor
-
54 litre Bucket
-
Hammer and Mallet
-
Metal Testing Cap
-
Two Foam Testing Stick
* The equipment must be owned by the applicant. The workshop
equipment ownership undertaking form must be completed
before workshop inspection.
(Rev.10/2016)
Top
Workshop
Facilities
FSI Contractors Classes 1, 2 & 3
Class
1, 2 & 3
An
independent workshop of area not less than 10 square meter shall
be provided. Documentary evidence (e.g. purchase / lease agreement)
to prove right of use of the workshop shall be produced.
w.e.f. 1 August 2002
Top
|